Like any other electrical installation, photovoltaic (PV) systems are subject to electrical faults, including arc faults, short circuits, ground faults and reverse currents, leading, in some cases, to result in fire. These faults and other failures of the system, including cable insulation breakdowns, rupture of a module, and faulty connections, can mean that areas of the system overheat, which can then ignite combustible material in its vicinity – posing a threat to nearby project infrastructure, personnel and the surrounding environment. Wrongly installed or defective DC/AC inverters have also been the cause of several damaging photovoltaic fires.

 

 

In the worst-case scenario, faulty conditions on the photovoltaic system will not only result in overheating, but might also cause a DC arc. There are three kinds of DC arcs:

  • Serial arcs: These occur when a connection is pulled apart while the PV is producing current. Typical reasons for serial arcs include loose connections or connector defects (e.g., in the soldered joints within the module). For this reason, special care should be taken when PV systems are isolated in a fire situation.
  • Parallel arcs: These occur when insulation systems of PV plants are damaged. Two conductors of opposite polarity in the same DC circuit are often run in close proximity to each other. The insulation between these two wires can become ineffective due to animals chewing on them, UV breakdown, embrittlement, cracking, moisture ingress and freeze / thaw cycles.
  • Ground arcs: These arcs occur on ground cables and can be triggered by a fault in any one single insulation system.

 

 

Currently, there is no single solution for mitigating the risk of DC arcs. The first line of defence should be high quality components, effective installation and the use of protective devices for the entire electrical system on a PV plant.

However, reliable detection of arc faults is a severe challenge for the industry and when arcs are detected, determining an appropriate corrective action is often difficult. Arcs must be reliably detected, without causing false alarms that can affect the operation of the park.

 

 

How can Greensolver help?

 

 

Greensolver, as technical and financial advisors, as well as asset managers, are able to assist with your solar PV needs and any aspects of your solar project in a number of ways. As we have been in the industry, managing and monitoring assets for over 12 years, Greensolver have a unique understanding of the potential issues that can happen with an asset. With this knowledge, we are able to provide expert advice in an advisorycommercial and technical capacity.

Blog

The Latest Renewable Energy News

Greensolver is the New Member of the UK’s Energy Storage Network

Press Release – Greensolver partners with Aevy to enhance asset management through AI-powered document intelligence

PRESS RELEASE – Greensolver partners with Tipspeed to strengthen wind farm performance services

Battery Energy Storage Systems with solar panels next to it

Greensolver will be in London for the Solar and Storage Live – April 29th

Wind farm with sunset

Greensolver will participate in the WindEurope 2026 in Madrid – April 21st

Battery Energy Storage Systems in a field with sunrising

Reshaping France’s Renewable Energy Market: The Role of BESS under PPE 3

Construction of solar panels with humans dressed for construction

Updates on Technical and Commercial Asset Management service in 2026

People smiling at corporate event

Greensolver will participate in the Energyear 2026 in Madrid – March 24 & 25

Solar panels in line

Design Choices That Define Lifetime Performance

Resources and insights A burning issue: managing PV plant fire